Technical Info
Hollowblocks produced in Balti Kivitehas Ltd are certified in Certification Centre of Tallinn University of Technology
hollow blocks |
| Measures (LxWxH)1 | mm | 390x240x190 | 390x190x190 | 390x140x190 | 390x90x190 |
| Tolerance class | D1 | D1 | D1 | D1 | |
| Weight2 | kg | 20 | 17 | 13 | 10 |
| Net dry density3 | kg/m3 | 2000 | 2000 | 2000 | 2000 |
| Gross dry density | kg/m3 | 1020 | 1040 | 1100 | 1380 |
| Masonry weight4 | kg/m2 | 270 | 232,5 | 182,5 | 145 |
| Filled part5 | % | 51 | 53 | 55 | 69 |
| Compressive strength6 | MPa | 18 | 18 | 18 | 18 |
| Compressive strength, Fb7 | N/mm2 | 12 | 9,54 | 9,90 | 12,42 |
| Frost resistance | mark | F56 | F56 | F56 | F56 |
| Water absorption8 | % | 8 | 8 | 8 | 8 |
| Capillary water absorption | g/m2xs0,5 | 208 | 208 | 208 | 208 |
| Water steam diffusion factor | 5/15 | 5/15 | 5/15 | 5/15 | |
| Airborne sound insulation index9 | db | 51/58 | 49/56 | 47/52 | 45/48 |
| Thermal resistance, R10 | m2xK/W | 0,26 | 0,24 | 0,21 | 0,19 |
| Equivalent coefficient of heat conductivity | W/mxK | 1,19 | 1,19 | 1,19 | 1,19 |
| Fire resistance11 | minut | Euroklass A1 | Euroklass A1 | Euroklass A1 | Euroklass A1 |
- Permitted measurement deviations: length, width, height +/- 2 mm
- Average hollow block weight in the condition of moisture content of 3-5%
- Minimum net dry density of a hollow block
- Minimum gross dry density of a hollow block
- Filled part indicates quantity of concrete in the block
- Average compressive strength to net cross-section of the surfaces in dry-air condition
- Normalised compressive strength of an aggregate masonry unit used in estimations as per EPN-ENV 6.1.1.
- Water absorption shall not exceed 8% of the weight of a hollow block
- Indicates water steam permeability in case of material with the given net dry density (table method)
- A reference value for given masonry (without aggregate/fully aggregated)
- A reference value for given masonry (without aggregate) Full aggregated =1.3
- Equivalent coefficient of heat conductivity is calculated based on the table method
- Although hollow blocks (aggregate masonry units) belong to non-combustive construction materials (class A1), it is not recommended to use these in places where temperatures may rise over 200°C
- Estimated, does not include weight of possible infill concrete and armouring (based on masonry mix consumption 20 kg/m2)
|
|
|
- Laius/pikkus ilma kivi külgedel asuvate vuugieenditeta (eendite paksus on 2 mm)
- Average pavement stone weight in the condition of moisture content of 3-5%
- Minimum net dry density of a pavement stone
- Compressive strength
- Water absorption shall not exceed 8% of the weight of a pavement stone